Olympus Omniscan SX 16:64 PR Phased Array Flaw Detector


The Olympus OmniScan SX features a new streamlined software interface displayed on an 8.4 in. (21.3 cm) touch screen. A single-group and non-modular instrument.

$12,550

Compare

2018 Olympus Omniscan SX 16:64 PR Phased Array Flaw Detector

With the OmniScan SX, Olympus proudly presents a defect detector that shares the OmniScan DNA and leverages over 20 years of phased array experience. An 8.4-inch (21.3-cm) touch screen displays the OmniScan SX’s new, simplified software interface for enhanced usability. For less demanding applications, the OmniScan SX is a cost-effective, single-group, non-modular device that is simple to use.

The OmniScan SX is available in two models: the SX PA and the SX UT. The SX PA is a 16:64PR phased array device that has a standard UT channel for TOFD, pitch-catch, or pulse-echo examination, just like the UT-only SX UT. The SX offers an unparalleled degree of portability for an OmniScan, being 50% smaller and 33% lighter than the OmniScan MX2.

Setting up an inspection can be done in NDT Setup Builder and then loaded straight into the OmniScan SX using an SD card or USB key. Acquisition can then start when a few simple instrument operations, including adjusting the gate and range, are completed. Additionally, the following features make it very simple to set up in the OmniScan SX:

  • Automatic probe recognition.
  • One-step, preconfigured application Wizard
  • Weld Overlay and RayTracing simulation

OmniScan SX Specifications:

Environmental Specifications

  • Operating temperature range: -10 C to 45 C (14 F to 113 F)
  • Storage temperature range: 20 C to 60 C (4 F to 140 F) with battery and 20 C to 70 C (4 F to 158 F) without battery
  • Relative humidity: Max. 70% RH at 45C noncondensing
  • Ingress protection rating: Designed to meet requirements of IP66
  • Shockproof rating: Drop-tested according to MIL-STD-810G 516.6

Included Accessories:

  • Olympus OmniScan SX 16:64 PA Flaw Detector
  • Battery Pack
  • AC Adapter
  • Power Cord
  • User Manual On Cd-ROM
  • Carrying Case

 

SKU: GB0009 Category: Tag: Brand:

Environmental Specifications

  • Operating temperature range: -10 C to 45 C (14 F to 113 F)
  • Storage temperature range: 20 C to 60 C (4 F to 140 F) with battery and 20 C to 70 C (4 F to 158 F) without battery
  • Relative humidity: Max. 70% RH at 45C noncondensing
  • Ingress protection rating: Designed to meet requirements of IP66
  • Shockproof rating: Drop-tested according to MIL-STD-810G 516.6

Power Supply

  • Battery type: Smart Li-ion battery
  • Number of batteries: 1
  • Battery life: Minimum 6 hours under normal operating conditions

Display

  • Display size: 21.3 cm (8.4 in.) (diagonal)
  • Resolution: 800 pixels x 600 pixels
  • Brightness: 600 cd/m2
  • Viewing angles: Horizontal: 80 to 80 Vertical: 60 to 80
  • Number of colors: 16 million
  • Type: TFT LCD

I/O Lines

  • Encoder: 2-axis encoder line (quadrature, up, down, or clock/ direction)
  • Digital input: 4 digital TTL inputs, 5 V
  • Digital output: 3 digital outputs TTL, 5 V, 15 mA maximum per output
  • Acquisition on/off switch: Yes, through configuration of a digital input
  • Pace input: 5 V TTL pace input

I/O Ports

  • USB ports: 2 USB ports, compliant with USB 2.0 specifications
  • Audio alarm: Yes
  • Video output: Video out (SVGA)

Beamforming

  • Scan type: Sectorial or linear
  • Group quantity: 1

Data Visualization

  • A-scan refresh rate: A-scan: 60 Hz; S-scan: 60 Hz

Data Synchronization

  • On internal clock: 1 Hz to 6 kHz
  • On encoder: On 2 axes: from 1 to 65,536 steps

Programmable Time-Corrected Gain (TCG)

  • Number of points: 16: One TCG (time-corrected gain) curve per focal law
  • Maximum slope: 40 dB/10 ns

Alarms

  • Number of alarms: 3
  • Conditions: Any logical combination of gates

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Olympus Omniscan SX 16:64 PR Phased Array Flaw Detector”

There are no reviews yet.